Detailed features

3 functions, more convenience

The SteamUP steriliser helps with several everyday tasks. It lets you sterilise accessories with steam, dry them with hot air or warm milk in a bottle. This means you do not need several separate appliances to keep things clean and prepare a meal for your child.

Thorough steam sterilisation

The SteamUP bottle steriliser can sterilise up to 4 bottles and accessories at the same time. Steam reaches all items evenly and removes up to 99.9% of bacteria and viruses without using chemicals. This keeps your child's accessories clean and safe for the next use.

Dry bottles without waiting

You can switch on the hot-air drying function to help bottles and accessories become dry and ready to use quickly. You do not need to wipe them or leave them to dry. The set also includes a practical holder for hot bottles, making it easier to remove warm items safely after the cycle has finished.

Automatic sterilisation and drying cycle

SteamUP performs two tasks in one programme: it first sterilises accessories with steam and then automatically dries them with hot air. This means you do not need to run each function separately or monitor every stage. You can choose from 3 programmes: 30, 40 or 50 minutes, making it easy to adjust the operating time to the number of bottles and accessories. It is a convenient solution that saves you time and simplifies daily care for your child.

Precise milk warming

With SteamUP, you can set the warming temperature yourself within a range of 37–85°C, making it easy to adjust it to the type of food. Within the range of 37–50°C, you can adjust the temperature in increments of 1°C, allowing you to set the milk temperature precisely. Above 50°C, the settings change in increments of 5°C. The built-in temperature probe monitors the heat and helps maintain the selected value, while the practical holder helps you remove the warmed bottle safely.

Dimensions

Dimension Value
Width (cm) 26 cm
Weight (g) 1950 g

Specifications

Sterilisation and drying

  • Number of bottles at once:

    Up to 4 bottles in the steriliser / 1 bottle for warming
  • Temperature range / levels:

    37–100°C (warming 37–85°C; sterilisation 100°C)
  • Overheat protection:

    Yes
  • Sterilisation time:

    30 / 40 / 50 min
  • Safety features:

    Low-water sensor; automatic shut-off; overheating protection
  • Number of bottles:

    Up to 4 bottles

Parameters, materials and power supply

  • Chamber capacity:

    Up to 4 bottles + accessories
  • Power:

    Steriliser power 600 W; drying power 150 W; bottle warmer power 90 W
  • BPA-free:

    Yes
  • Power supply type:

    Mains-powered

Included in the set

Holder for hot bottles

Holder for hot bottles

After the cycle has finished, the holder helps you remove warm bottles and accessories. It helps you move them without handling them directly with your hands.

Bottle stand

Bottle stand

The stand lets you arrange several bottles neatly at the same time. It helps you prepare them for sterilisation in the device chamber.

Warmer basket

Warmer basket

During warming, the basket helps keep the bottle securely in place in the device. This helps you insert and remove after use.

Water measuring cup

Water measuring cup

The cup helps you measure the water needed to prepare the device for use. It is useful for adding water before everyday use.

Delivery & returns

Returns

You have 100 days to return your order free of charge, with no reason required.

Warranty

12-year warranty with Lionelo Protect after registration.

Delivery

Dispatch within 24 hours. Free delivery on orders over €119.

FAQ

How do I prepare the STEAMUP steriliser before first use?

Place the STEAMUP steriliser on a dry, stable, heat-resistant surface. Add 70 ml of water for Auto mode and 100 ml for sterilisation mode. Do not add water when using drying mode, and follow the specified quantities to avoid flooding the motor.

How do I start Auto mode on the STEAMUP steriliser?

In standby mode, add 70 ml of water and select Auto mode. The default cycle lasts 40 minutes; press the button again to set 50 or 30 minutes. After the display flashes three times, the device will start: sterilisation lasts 10 minutes, followed automatically by drying. The fan continues running for another 2 minutes to cool the motor.

How do I set the sterilisation time on the STEAMUP steriliser?

In standby mode, add 100 ml of water and select sterilisation mode. Each press of the button adds 1 minute, with a setting range of 8 to 15 minutes. After the display flashes three times without any further changes, the device will start sterilising. A sound and the mode indicator switching off will signal the end of the cycle.

How do I select the drying time on the STEAMUP steriliser?

In standby mode, select drying mode without adding water. Press the button repeatedly to set 30, 40, 50 or 60 minutes; the selected time appears on the LED display. After the display flashes three times, the device will start operating, and it will show “00” when the cycle is complete. The fan continues running for another 2 minutes to cool the motor.

How do I set the warming temperature on the STEAMUP steriliser?

In standby mode, select warming and use the button to set the temperature. Between 35–50°C, it changes in increments of 1°C, and from 50°C to 85°C in increments of 5°C. Once the display stops flashing, the device will start warming, which takes 10 to 30 minutes depending on the starting temperature. The display shows the temperature of the container, so shake the bottle and check the food temperature before feeding.

How do I start automatic warming mode on the STEAMUP steriliser?

In standby mode, start automatic warming mode and set the operating time. You can choose a setting of 40 or 50 minutes. Select the time before starting the cycle.

How do I safely clean the STEAMUP steriliser after use?

First, unplug the STEAMUP steriliser and leave it to cool. Wash the lid, trays, column, adapter, clips and other components by hand with water and a mild detergent. Wipe the main housing and base with a damp cloth. Do not immerse the base in water or pour water over it. Once dry, assemble the device or store it in a dry place.

How do I descale the STEAMUP steriliser step by step?

Unplug the STEAMUP steriliser and make sure the heating plate has cooled down. Prepare a solution of 50 ml vinegar and 50 ml hot water, then pour it directly onto the metal heating plate in the base. Leave it for approximately 30 minutes, pour out the liquid and wipe the plate with a clean, damp cloth to remove any residue. Finally, dry it with a soft cloth or leave it to air-dry.

How do I prepare the STEAMUP steriliser before first use?

Place the STEAMUP steriliser on a dry, stable, heat-resistant surface. Add 70 ml of water for Auto mode and 100 ml for sterilisation mode. Do not add water when using drying mode, and follow the specified quantities to avoid flooding the motor.

Manufacturer

BrandLine Group Sp. z o.o. is the manufacturer of Lionelo products.

Manufacturer’s address: ul. Adama Kręglewskiego 1, 61-248 Poznań, Poland.

Contact: shop@lionelo.com

This information is provided in accordance with GPSR requirements concerning the identification of the manufacturer and contact details for products placed on the EU market.